Smokeless Heat

News

Final Stages of EPA Method 28 WHH-PTS Testing for Vedolux Boilers

Testing for the non-lambda boilers shows that these model types will still be a viable solution even after the 2020 EPA emissions levels take effect.

Now for the scores. If you compare these to the current list of cord-wood boilers on the EPA site, you will see that they score very well.

The test method is Method 28 WHH-PTS. It uses real cord wood rather than cribs, and emissions are collected from the match to the end of the burn. Our boilers have always been full thermal-storage type boilers and will continue to be under the new rules. The required thermal storage is quite close to what each current manual lists as required. Updated manuals will list the minimum thermal storage values each boiler was tested with, which will now be mandated for every installation.

Model lb/mmBtu (weighted annual average)
Non-Lambda
Vedolux 30 0.17
Vedolux 37 0.11
Vedolux 55 0.11
Lambda
Vedolux 350 0.08
Vedolux 450 0.04
Vedolux 650 0.08

Page from the V37 test copy draft showing the values:

V37 test draft showing values

Originally published: October 2016