The used propane tanks shown in this video are stacked and used for water storage with a Vedolux 50 natural draft boiler. The video below shows the lighting sequence. A draft booster is installed in the flue, but it was not used for this lighting. The draft booster can be used during lighting if a weather system creates back pressure or otherwise poor draft. The tanks will be fully insulated after the system has been operated for a while.
With two 500-gallon tanks, the 1,000 gallons of total water volume is a good fit for the output of the natural draft Vedolux 50. The storage tanks are propane tanks that have been taken out of service by the gas company. They are steam cleaned, and modifications such as ports and legs are added where necessary. The stacked tanks provide very good stratification. The radiant floors in the new addition are heated exclusively from the wood system, and a primary loop runs over to the oil boiler, which becomes the heat source if the tank temperature exceeds 140 degrees.
This natural draft boiler offers downdraft gasification burning without an integrated fan. Because the stack temperatures of the natural draft boilers offered by Varmebaronen need to be about 50–100 degrees higher than their suction fan counterparts, the efficiency of the natural draft boiler is 5–10% lower than the suction fan models. The higher stack temperature is needed to maintain the required air velocity.
This system heats an old farmhouse with a new addition in central PA.
Video
Originally published: March 2015